Specifications
Input Voltages | CSA 120–230 V, 1-PH, 50/60 Hz CE 120–230 V, 1-PH, 50/60 Hz |
Input Current @ 2.49 kW | CSA 120 – 230 V, 1-PH, 26 – 13.5 A CE 120 – 230 V, 1-PH, 26 – 13.5 A |
Output current | 15–30 A |
Rated output voltage | 83 VDC |
Duty cycle @ 40 °C (104° F) | CSA 50% @ 230 V 35% @ 120 V CE 50% 230 V 35% 120 V |
Open circuit voltage (OVC) | 240 VDC |
Dimensions w/ handles | 14.0" (356 mm) D; 6.6" (168 mm) W; 12.0" (305 mm) H |
Weight w/ 15' torch | CSA 20 lbs (9.7 kg) CE 21 lbs (10 kg) |
Gas Supply | Clean, dry, oil-free air or nitrogen |
Recommended gas inlet flow rate/pressure | 240 scfh (113 l/min) @ 80 psi (5.5 bar) |
Input power cable length | 10' (3 m) |
Power supply type | Inverte - IGBT |
Engine-driven Generator
Engine Drive Rating (kW) | System Output (amps) | Performance (arc stretch) |
---|---|---|
5.5 | 30 | Full |
4 | 25 | Limited |
Cut Chart
Material | Thickness | Current (amps) | Max Cut Speed* | ||
---|---|---|---|---|---|
in | mm | ipm | mm/min | ||
Mild Steel | 18 GA 10 GA 3/16 1/4 3/8 | 1 3 5 6 10 | 30 30 30 30 30 | 394 87 52 33 15 | 10007 2210 1321 838 381 |
Stainless Steel | 18 GA 10 GA 1/4 3/8 | 1 3 6 10 | 30 30 30 30 30 | 399 78 26 11 | 10135 1981 660 279 |
Aluminum | 18 GA 10 GA 1/4 3/8 | 1 3 6 10 | 30 30 30 30 30 | 221 55 24 11 | 5613 1397 610 279 |
* Maximum cut speeds are the results of Hypertherm’s laboratory testing. For optimum cut performance, actual cutting speeds may vary based on different cutting applications. Refer to the operator manual for more details.